            COATRON X-Series (ECO / Pro / TOP)
                The Coatron X instrument line is a consequent continuation in the development of the Coatron product line. Over 25 years in experience and innovation is the reference for our new Coatron X instrumentation line.
                
              
                
                  
                    Highest optical resolution, enlarged optic range, smallest sample and reagent volume
                  
                
                
                0,1 mOD – 3500 mOD, just with 75μL sample and reagent volume
                
                
                  
                    Complete optical analysis
                  
                
                
                No further parts required, like balls, stirrers etc.
                
                
                  
                    Adaptation of the light level
                  
                
                
                Automatic light level adjustment of the optic channels to each sample
                
                
                  
                    Exclusion of disturbance
                  
                
                
                Stray light reduction, exact temperature control, all parameter are preset
                
              
TECO X-ECO
10 Pre Warms Cuvettes
- 
                    1 Pre-warm reagent 24mm 
                    
 
- 
                    2 Pre-warm reagent 22mm
                    
 
- 
                    2 Pre-warm reagent 11mm
                    
 
- 
                    0 Reagent mixing position
                    
 
- 
                    1 Optic channels
                    
 
- 
                    620 (red) Wavelength (nm)
                    
 
TECO X-PRO
20 Pre Warms Cuvettes
- 
                    1 Pre-warm reagent 24mm
                    
 
- 
                    2 Pre-warm reagent 22mm
                    
 
- 
                    2 Pre-warm reagent 11mm
                    
 
- 1 Reagent mixing position
- 
                    2 Optic channels
                    
 
- 
                    405 (UV) Wavelength (nm)
                    
 
TECO X-TOP
20 Pre Warms Cuvettes
- 
                    1 Pre-warm reagent 24mm
                    
 
- 
                    2 Pre-warm reagent 22mm
                    
 
- 
                    2 Pre-warm reagent 11mm
                    
 
- 1 Reagent mixing position
- 
                    4 Optic channels
                    
 
- 
                    405  (UV) Wavelength (nm)
                    
 
 
               
               
               
               
               
               
              